What should we improvement

Style
Speed
projection
structure
communion

       
 

       

THE CODE INNITIAL SETUP INSTRUCTION FOR ST48/ZN48/ZN72

The  Code Initial Setup Instruction for ST48/ZN48/ZN72 Series Intelligent Dual Digital Display Meters
  Before delivery of the ST48/ZN48/ZN72Series productstheir code numbers are set as 08-1its related product model is as Single Set Dual Digital Display 4-digit Time Relay, Model Number: ZN48S-3/72S-3(1S-99M59S)the relay operation mode is time delayed ON type
Notethe ^x ̄ in the following table is for relay operation mode, its value is 1-6(refer to ̄. Relay Operation Mode ̄ for details), and related specific meaning is as follows;
The Product Code Number Table                                                        
Code
Model
Display range
Remarks
01-X
ZN48S--6
0.01s!99.99s
Elapsed time (Up) time delay
02-X
ZN48S--1
0.01s!99.99s
Remaining time (Down)time delay
03-X
ZN48S--10
1M!9999M
Elapsed time (Up) time delay
04-X
ZN48S--5
1M!9999M
Remaining time (Down)time delay
05-X
ZN48S--7
1S!9999S
Elapsed time (Up) time delay
06-X
ZN48S--2
1S!9999S
Remaining time (Down)time delay
07-X
ZN48S--8
1S-99M59S
Elapsed time (Up) time delay
08-X
ZN48S--3
1S-99M59S
Remaining time (Down)time delay
09-X
N48S--9
1M-99H59M
Elapsed time (Up) time delay
10-X
ZN48S--4
1M-99H59M
Remaining time (Down)time delay
11-X
ZN48SS--8
1M-99H59M
 
12-X
ZN48SS--4
1M-99H59M
Remaining time (Down)time delay
13-X
ZN48SS--6
1S-99M59S
Elapsed time (Up) time delay
14-X
ZN48SS--2
1S-99M59S
Remaining time (Down)time delay
15-X
ZN48SS--5
1S!9999S
Elapsed time (Up) time delay
16-X
ZN48SS--1
1S!9999S
Remaining time (Down)time delay
17-X
ZN48SS--7
1M-9999M
Elapsed time (Up) time delay
18-X
ZN48SS--3
1M-9999M
Remaining time (Down)time delay
19-X
ZN48L-4
0-99H59M59.99S
Immediately reset
20-X
ZN48L-1
0-99H59M59.99S
8 seconds reset
21-X
ZN48L-5
0-9999H59M59S
Immediately reset
22-X
ZN48L-2
0-9999H59M59S
8 seconds reset
23-X
ZN48L-3
0-9999D23H59M
Immediately reset
24-X
ZN48L-6
0-9999D23H59M
8 seconds reset
25-X
ZN48F-1
1Hz-9999 Hz
 
26-X
ZN48F-2
0.1Hz-999.9 Hz
 
27-X
ZN48N
60!9999RPM One pulse per rpm
28-X
ZN48FR
0!9999 General purpose for frequency and rotation speed
29-X
ZN48J
0-99999999-0 Short connection COM and PAU
30-X
ZN48JR
0-9999.999(9999.999-0 Short connection COM and PAU)
31-X
ZN48J8
0-99999999(99999999-0 Short connection COM and PAU)
32-X
ZN48J8R
0-99999999.999(99999999.999-0 Short connection COM and PAU)
 

Add:Sanhe Nanli West,Xing ye St,Daxing District,Beijing P.R.C.
Tel+86 10 69203006 EXT  Fax+86 10 60259842    Zip:100076
Web http://www.symore.com E-mail:st48_cn@yahoo.com.cn